Helical cone beam computed tomography

You don't need to be Editor-In-Chief to add or edit content to WikiDoc. You can begin to add to or edit text on this WikiDoc page by clicking on the edit button at the top of this page. Next enter or edit the information that you would like to appear here. Once you are done editing, scroll down and click the Save page button at the bottom of the page.

(Redirected from Helical CT scan)
Jump to: navigation, search

Helical (or spiral) cone beam computed tomography is a type of three dimensional computed tomography (CT) in which the source (usually of x-rays) describes a helical trajectory relative to the object while a two dimensional array of detectors measures the transmitted radiation on part of a cone of rays eminating from the source. Willi Kalender, who is credited with the invention prefers the term Spiral scan CT, arguing that spiral is synonymous with helical: for example as used in 'spiral staircase'.

In practical helical cone beam x-ray CT machines the source and array of detectors are mounted on a rotating gantry while the patient is moved axially at a uniform rate. Earlier x-ray CT scanners imaged one slice at a time by rotating source and one dimensional array of detectors while the patient remained static. The helical scan method reduces the x-ray dose to the patient required for a given resolution while scanning more quickly. This is however at the cost of greater mathematical complexity in the reconstruction of the image from the measurements.

Since its invention by Kalender in the 1980s, helical scan CT machines have steadily increased the number of rows of detectors (slices) they deploy. The first prototype 16 multislice scanner was introduced in 2001 and in 2004, 64 multislice scanners are on the market. These can produce an image in less than a second and thus can obtain images of the heart and its blood vessels (coronary vessels) as if frozen in time.

External links


Acknowledgement and Attribution Regarding Sources of Content

Some of the initial content on this page may be incorporated in part from copyleft sources in the public domain including wikis such as Wikipedia and AskDrWiki. Drug information for patients came from the The National Library of Medicine. Infectious disease information may have come from the Centers for Disease Control (CDC). Differential Diagnoses are drawn from clinicians as well as an amalgamation of 3 sources: 1.The Disease Database; 2. Kahan, Scott, Smith, Ellen G. In A Page: Signs and Symptoms. Malden, Massachusetts: Blackwell Publishing, 2004:3; 3. Sailer, Christian, Wasner, Susanne. Differential Diagnosis Pocket. Hermosa Beach, CA: Borm Bruckmeir Publishing LLC, 2002:7 .

Personal tools