Magic angle

You don't need to be Editor-In-Chief to add or edit content to WikiDoc. You can begin to add to or edit text on this WikiDoc page by clicking on the edit button at the top of this page. Next enter or edit the information that you would like to appear here. Once you are done editing, scroll down and click the Save page button at the bottom of the page.

Jump to: navigation, search

This article is about the magic angle as defined in the field of nuclear magnetic resonance spectroscopy. For the magic angle as defined in the field of electron energy-loss spectroscopy see magic angle (EELS).

The magic angle is a precisely defined angle, the value of which is approximately 54.7°. The magic angle is a root of a second-order Legendre polynomial, P_2(\cos\theta)=0 \,, and so any interaction which depends on this second-order Legendre polynomial vanishes at the magic angle. This property makes the magic angle of particular importance in solid-state NMR spectroscopy.

Mathematical definition

The magic angle θm is

 \theta_m = \rm{arccos}\frac{1}{\sqrt{3}} = \rm{arctan}\sqrt{2} \approx 54.7^\circ,

where arccos and arctan are the inverse cosine and tangent functions respecively.

θm is the angle between the space diagonal of a cube and any of its three connecting edges, see image.

Magic angle and dipolar coupling

In nuclear magnetic resonance (NMR) spectroscopy, in a strong magnetic field, the dipolar coupling D depends on the orientation of the internuclear vector with the external magnetic field by

D(\theta) \propto 3\cos^2\theta - 1

Hence, two nuclei with a dipolar coupling vector at an angle of θm to a strong external magnetic field, have zero dipolar coupling, D(θm)=0. Magic angle spinning is a technique in solid-state NMR spectroscopy, which employs this principle to remove or reduce dipolar couplings, thereby increasing spectral resolution.

Application to medical imaging: The magic angle artifact

The magic angle artifact refers to the increased signal on sequences with short echo time (e.g., T1 or PD Spin Echo sequences ) in MR images seen in tissues with well-ordered collagen fibers in one direction (e.g., tendon or articular hyaline cartilage). This artifact occurs when the angle such fibers make with the magnetic field is equal to θm (Bydder et al, 2007).

References

  • Bydder M, Rahal A, Fullerton G, Bydder G (2007). "The magic angle effect: a source of artifact, determinant of image contrast, and technique for imaging". Journal of magnetic resonance imaging : JMRI 25 (2): 290-300. PMID 17260400.
WikiDoc Help Menu

Quick Start..

Editing basics

Advanced editing

Communicating your edits

Help Videos You Can Watch


Acknowledgement and Attribution Regarding Sources of Content

Some of the initial content on this page may be incorporated in part from copyleft sources in the public domain including wikis such as Wikipedia and AskDrWiki. Drug information for patients came from the The National Library of Medicine. Infectious disease information may have come from the Centers for Disease Control (CDC). Differential Diagnoses are drawn from clinicians as well as an amalgamation of 3 sources: 1.The Disease Database; 2. Kahan, Scott, Smith, Ellen G. In A Page: Signs and Symptoms. Malden, Massachusetts: Blackwell Publishing, 2004:3; 3. Sailer, Christian, Wasner, Susanne. Differential Diagnosis Pocket. Hermosa Beach, CA: Borm Bruckmeir Publishing LLC, 2002:7 .