Soft laser desorption
You don't need to be Editor-In-Chief to add or edit content to WikiDoc. You can begin to add to or edit text on this WikiDoc page by clicking on the edit button at the top of this page. Next enter or edit the information that you would like to appear here. Once you are done editing, scroll down and click the Save page button at the bottom of the page.
| Soft laser desorption | |
|---|---|
| Acronym | SLD |
| Classification | Mass spectrometry |
| Analytes | Biomolecules Synthetic polymers |
| Other Techniques | |
| Related | Matrix-assisted laser desorption/ionization Surface-enhanced laser desorption/ionization |
Soft laser desorption is laser desorption of large molecules that results in ionization without fragmentation. "Soft" in the context of ion formation means forming ions without breaking chemical bonds. "Hard" ionization is the formation of ions with the breaking of bonds and the formation of fragment ions.
Background
The term "soft laser desorption" has not been widely used by the mass spectrometry community, which in most cases uses matrix-assisted laser desorption/ionization (MALDI) to indicate soft laser desorption ionization that is aided by a separate matrix compound. The term soft laser desorption was used most notably by the Nobel Foundation in public information released in conjunction with the 2002 Nobel Prize in Chemistry.[1] Koichi Tanaka was awarded 1/4 of the prize for his use of a mixture of cobalt nanoparticles and glycerol in what he called the “ultra fine metal plus liquid matrix method” of laser desorption ionization. With this approach, he was able to demonstrate the soft ionization of proteins.[1] The MALDI technique was demonstrated (and the name coined) in 1985 by Michael Karas, Doris Bachmann, and Franz Hillenkamp,[1] but ionization of proteins by MALDI was not reported until 1988, immediately after Tanaka's results were reported.
Some have argued that Karas and Hillenkamp were more deserving of the Nobel Prize than Tanaka because their crystalline matrix method is much more widely used than Tanaka's liquid matrix.[1][1] Countering this argument is the fact that Tanaka was the first to use a 337 nm nitrogen laser while Karas and Hillenkamp were using a 266 nm Nd:YAG laser. The "modern" MALDI approach came into being several years after the first soft laser desorption of proteins was demonstrated.[1][1][1]
Examples in mass spectrometry
The matrix-assisted laser desorption/ionization approach[1] typically uses a small organic acid solid matrix, although liquids have been used. The light source is a pulsed IR or UV laser. The surface-enhanced laser desorption/ionization (SELDI) variand is similar to MALDI, but uses a biochemical affinity target.[1][1] The technique known as surface-enhanced neat desorption (SEND)[1] is a variant of MALDI with the matrix is covalently linked to the target surface.The surface-assisted laser desorption/ionization (SALDI) approach[1] can be described as MALDI using a liquid plus particulate matrix. The desorption ionization on silicon (DIOS) approach[1] is laser desorption/ionization of a sample deposited on a porous silicon surface. The technique known as laser induced acoustic desorption (LIAD ) is transmission geometry LDI with a metal film target.[1][1]
See also
References
External links
Acknowledgement and Attribution Regarding Sources of Content
Some of the initial content on this page may be incorporated in part from copyleft sources in the public domain including wikis such as Wikipedia and AskDrWiki. Drug information for patients came from the The National Library of Medicine. Infectious disease information may have come from the Centers for Disease Control (CDC). Differential Diagnoses are drawn from clinicians as well as an amalgamation of 3 sources: 1.The Disease Database; 2. Kahan, Scott, Smith, Ellen G. In A Page: Signs and Symptoms. Malden, Massachusetts: Blackwell Publishing, 2004:3; 3. Sailer, Christian, Wasner, Susanne. Differential Diagnosis Pocket. Hermosa Beach, CA: Borm Bruckmeir Publishing LLC, 2002:7 .