Sphygmomanometer

You don't need to be Editor-In-Chief to add or edit content to WikiDoc. You can begin to add to or edit text on this WikiDoc page by clicking on the edit button at the top of this page. Next enter or edit the information that you would like to appear here. Once you are done editing, scroll down and click the Save page button at the bottom of the page.

Jump to: navigation, search

Please Take Over This Page and Apply to be Editor-In-Chief for this topic: There can be one or more than one Editor-In-Chief. You may also apply to be an Associate Editor-In-Chief of one of the subtopics below. Please mail us [1] to indicate your interest in serving either as an Editor-In-Chief of the entire topic or as an Associate Editor-In-Chief for a subtopic. Please be sure to attach your CV and or biographical sketch.

Overview

BP 126/70 mmHg as result on electronic sphygmomanometer
BP 126/70 mmHg as result on electronic sphygmomanometer

A sphygmomanometer (often condensed to sphygmometer[2]) or blood pressure meter is a device used to measure blood pressure, comprising an inflatable cuff to restrict blood flow, and a mercury or mechanical manometer to measure the pressure. It is always used in conjunction with a means to determine at what pressure blood flow is just starting, and at what pressure it is unimpeded. Manual sphygmomanometers are used in conjunction with a stethoscope.

The word comes from the Greek sphygmós (pulse), plus the scientific term manometer (pressure meter). The device was invented by Samuel Siegfried Karl Ritter von Basch. Scipione Riva-Rocci, an Italian physician, introduced a more easily used version in 1896. Harvey Cushing discovered this device in 1901 and popularised it.

A sphygmomanometer usually consists of an inflatable cuff, a measuring unit (the mercury manometer), a tube to connect the two, and (in models that don't inflate automatically) an inflation bulb also connected by a tube to the cuff. The inflation bulb contains a one-way valve to prevent inadvertent leak of pressure while there is an adjustable screw valve for the operator to allow the pressure in the system to drop in a controlled manner.

Operation

The cuff is normally placed around the upper left arm, at roughly the same vertical height as the heart while the subject is in an upright position. The cuff is inflated until the artery is completely occluded. Listening with a stethoscope to the brachial artery at the elbow, the examiner slowly releases the pressure in the cuff. As the pressure in the cuffs falls, a "whooshing" or pounding sound is heard (see Korotkoff sounds) when bloodflow first starts again in the artery. The pressure at which this sound began is noted and recorded as the systolic blood pressure. The cuff pressure is further released until the sound can no longer be heard and this is recorded as the diastolic blood pressure.

Significance

The peak pressure in the arteries during the cardiac cycle is the systolic pressure, and the lowest pressure (at the resting phase of the cardiac cycle) is the diastolic pressure.

Types

There are two types:

  1. Digital (electronic, easy to operate and practical in noisy environment. Many have not been validated for all patient groups, and can give very inaccurate readings).They measure mean arterial pressure, MAP, and use algorithms to calculate systolic and diastolic values. In this sense, they do not actually measure the blood pressure, but derive the readings. Digital oscillometric monitors are also confronted with “special conditions” for which they are not designed to be used : arteriosclerosis, arrhythmia, preeclampsia, pulsus alternans, and pulsus paradoxus.
  2. Manual (older fashioned, though more precise). Must be operated by a trained person.

Mercury manometers are considered to be the "Gold Standard" of measurement because they do not go out of calibration. For this reason they are often required in clinical trials of pharmaceuticals and for clinical evaluations of determining blood pressure for high risk patients including pregnant women. Aneroid, mechanical, types are in common use, but should be checked against a mercury manometer if they are suspected to be out of calibration.

Gallery

See also

More detail is given in the article on blood pressure.

Patents

de:Blutdruckmessgerätfa:بازوبند فشار خون fr:Tensiomètre it:Sfigmomanometro nl:Bloeddrukmeter ja:血圧計 pms:Sfigmomanòmetersl:Sfigmomanometer fi:Verenpainemittari

WikiDoc Help Menu

Quick Start..

Editing basics

Advanced editing

Communicating your edits

Help Videos You Can Watch


Acknowledgement and Attribution Regarding Sources of Content

Some of the initial content on this page may be incorporated in part from copyleft sources in the public domain including wikis such as Wikipedia and AskDrWiki. Drug information for patients came from the The National Library of Medicine. Infectious disease information may have come from the Centers for Disease Control (CDC). Differential Diagnoses are drawn from clinicians as well as an amalgamation of 3 sources: 1.The Disease Database; 2. Kahan, Scott, Smith, Ellen G. In A Page: Signs and Symptoms. Malden, Massachusetts: Blackwell Publishing, 2004:3; 3. Sailer, Christian, Wasner, Susanne. Differential Diagnosis Pocket. Hermosa Beach, CA: Borm Bruckmeir Publishing LLC, 2002:7 .

Personal tools