Starling equation

You don't need to be Editor-In-Chief to add or edit content to WikiDoc. You can begin to add to or edit text on this WikiDoc page by clicking on the edit button at the top of this page. Next enter or edit the information that you would like to appear here. Once you are done editing, scroll down and click the Save page button at the bottom of the page.

(Redirected from Starling forces)
Jump to: navigation, search

Please Take Over This Page and Apply to be Editor-In-Chief for this topic: There can be one or more than one Editor-In-Chief. You may also apply to be an Associate Editor-In-Chief of one of the subtopics below. Please mail us [1] to indicate your interest in serving either as an Editor-In-Chief of the entire topic or as an Associate Editor-In-Chief for a subtopic. Please be sure to attach your CV and or biographical sketch.

Formulated in 1896 by the British physiologist Ernest Starling, the Starling equation illustrates the role of hydrostatic and oncotic forces (the so-called Starling forces) in the movement of fluid across capillary membranes.

Capillary fluid movement may occur as a result of two processes:

  • diffusion
  • filtration

Starling's equation only refers to fluid movement across the capillary membrane that occurs as a result of filtration. In the glomerular capillaries, there is a net fluid filtration of 125 ml/min (about 180 litres/day). In the rest of the body's capillaries, there is a total net transcapillary fluid movement of 20 ml/min (about 28.8 litres/day) as a result of filtration. This is several orders of magnitude lower than the total diffusional water flux at the capillary membrane, as that is about 80,000 litres/day.

The equation

The Starling equation reads as follows:

Jv = Kf([PcPi] − σ[πc − πi])

where:

  • ([PcPi] − σ[πc − πi]) is the net driving force,
  • Kf is the proportionality constant, and
  • Jv is the net fluid movement between compartments.

By convention, outward force is defined as positive, and inward force is defined as negative. The solution to the equation is known as the net filtration or net fluid movement (Jv). If positive, fluid will tend to leave the capillary (filtration). If negative, fluid will tend to enter the capillary (absorption). This equation has a number of important physiologic implications, especially when pathologic processes grossly alter one or more of the variables.

The variables

According to Starling's equation, the movement of fluid depends on six variables:

  1. Capillary hydrostatic pressure ( Pc )
  2. Interstitial hydrostatic pressure ( Pi )
  3. Capillary oncotic pressure ( πc )
  4. Interstitial oncotic pressure ( πi )
  5. Filtration coefficient ( Kf )
  6. Reflection coefficient ( σ )

Pressures are often measured in millimeters of mercury (mmHg), and the filtration coefficient in milliliters per minute per millimeter of mercury (ml·min-1·mmHg-1).

In essence the equation says that the net filtration (Jv) is proportional to the net driving force. The first four variables in the list above are the forces that contribute to the net driving force.

Filtration coefficient

The filtration coefficient is the constant of proportionality. A high value indicates a highly water permeable capillary. A low value indicates a low capillary permeability.

The filtration coefficient is the product of two components:

  • capillary surface area
  • capillary hydraulic conductance

Reflection coefficient

The reflection coefficient is often thought of as a correction factor. The idea is that the difference in oncotic pressures contributes to the net driving force because most capillaries in the body are fairly impermeable to the large molecular weight proteins. (The term ultrafiltration is usually used to refer to this situation where the large molecules are retained by a semipermeable membrane but water and low molecular weight solutes can pass through the membrane).

Many body capillaries do have a small permeability to proteins (such as albumins). This small protein leakage has two important effects:

  • the interstitial fluid oncotic pressure is higher than it would otherwise be in that tissue
  • not all of the protein present is effective in retaining water so the effective capillary oncotic pressure is lower than the measured capillary oncotic pressure.

Both these effects decrease the contribution of the oncotic pressure gradient to the net driving force. The reflection coefficient (σ) is used to correct the magnitude of the measured gradient to 'correct for' for the ineffectiveness of some of the oncotic pressure gradient. It can have a value from 0 up to 1.

  • Glomerular capillaries have a reflection coefficient close to 1 as normally no protein crosses into the glomerular filtrate.
  • In contrast, hepatic sinusoids have a low reflection coefficient as they are quite permeable to protein. This is advantageous because albumin is produced in hepatocytes and can relatively freely pass from these cells into the blood in the sinusoids. The predominant pathway for albumin and other proteins to enter the circulation is via the lymph.

Clinical usefulness

The equation is very useful for explaining what is happening at the capillary, but has very limited clinical usefulness. Mostly this reflects the impossibility of easily measuring all six variables together in actual patients.

See also

External links


WikiDoc Help Menu

Quick Start..

Editing basics

Advanced editing

Communicating your edits

Help Videos You Can Watch


Acknowledgement and Attribution Regarding Sources of Content

Some of the initial content on this page may be incorporated in part from copyleft sources in the public domain including wikis such as Wikipedia and AskDrWiki. Drug information for patients came from the The National Library of Medicine. Infectious disease information may have come from the Centers for Disease Control (CDC). Differential Diagnoses are drawn from clinicians as well as an amalgamation of 3 sources: 1.The Disease Database; 2. Kahan, Scott, Smith, Ellen G. In A Page: Signs and Symptoms. Malden, Massachusetts: Blackwell Publishing, 2004:3; 3. Sailer, Christian, Wasner, Susanne. Differential Diagnosis Pocket. Hermosa Beach, CA: Borm Bruckmeir Publishing LLC, 2002:7 .

Personal tools
In other languages